NVIDIA H200 GPU + NVSwitch Liquid Cooling Assembly — US Data Centers
ToneCooling Texas supports US AI-server, HPC, and data-center teams with a complete liquid cooling assembly for 8× NVIDIA H200 GPUs and 4× NVSwitch devices — validated to 6.344 kW, 100% helium leak tested, US-hours DFM review, and prototype coordination.
- 2D or 3D drawings
- Heat load and heat-source map
- Coolant, flow rate, and pressure-drop limit
- Envelope, mounting, and port layout
- Material and joining preference
- Prototype quantity and annual volume
ToneCooling Texas LLC coordinates US RFQs for the NVIDIA H200 GPU + NVSwitch liquid cooling assembly — a complete kit with 8 copper GPU cold plates, 4 copper NVSwitch cold plates, dual inlet/outlet manifolds, EPDM flexible hoses, and leak-free quick disconnects. US-hours DFM review, engineer-reviewed RFQs, and production through our 30,000 m² ISO 9001:2015-certified, IATF 16949-aligned facility in Huizhou, China.
Complete liquid cooling assembly for NVIDIA H200 data centers
ToneCooling Texas supports US AI-server OEMs, HPC integrators, and data-center operators with a complete direct-to-chip liquid cooling assembly for NVIDIA H200 GPU + NVSwitch baseboards. Designed for high-density AI servers, HPC systems, and data centers requiring high cooling capacity, low pressure drop, and verified reliability.
For platform-level specifications published by NVIDIA, see the official NVIDIA H200 Tensor Core GPU product page (external reference, no partnership implied). This page is owned by the USA market site (usa intent) and does not compete with the global manufacturing hub (tonecooling.com) or the Australia support site.
NVIDIA H200 liquid cooling assembly — typical validated specs
| Supported devices | H200 GPU × 8 + NVSwitch × 4 |
|---|---|
| Total heat load | 700 W × 8 + 186 W × 4 = 6.344 kW |
| Inlet water temperature | 45°C |
| Maximum component temperature | below 80°C |
| Recommended flow rate | 10 LPM |
| Maximum pressure drop | 40 kPa |
| Maximum operating pressure | 1 MPa |
| System thermal resistance | below 0.0055 °C/W |
| Cold plate material / finish | Copper, electroless nickel plating |
| Other metal parts | Stainless steel / aluminium, anodized / passivated |
| Connection type | Quick disconnect coupling |
| Overall dimensions (L × W × H) | 409.18 × 331 × 139.61 mm |
Specifications are typical validated values at the stated working point; final values are confirmed per drawing, heat load, flow rate, pressure-drop limit, and annual volume.
What’s included in the assembly
| GPU cold plates | 8 × high-performance copper cold plate, one per H200 GPU |
|---|---|
| NVSwitch cold plates | 4 × high-performance copper cold plate, one per NVSwitch device |
| Manifolds | 2 × inlet / outlet manifold with integrated flow distribution |
| Hose assemblies | 12 × EPDM hose with braid, high-temperature and corrosion-resistant |
| Quick disconnects | 12 × leak-free quick disconnect, color-coded (red = outlet, blue = inlet) |
| Mounting hardware | 1 set — screws, spacers, brackets, and other installation parts |
Verified per-unit test results
| Helium leak test | 100% tested, <1.0×10-9 Pa·m³/s |
|---|---|
| Pressure test | 1 MPa for 5 minutes, no leakage |
| Thermal performance | Validated under full-load conditions |
| Corrosion resistance | Test passed |
| Cleanliness | Suitable for pure-water cooling systems |
Industrial cold plates vs. consumer liquid cooling — why it matters for AI server deployment
Searches for NVIDIA H200 liquid cooling also surface consumer and enthusiast PC water-cooling brands. Those products are built for single-GPU desktop builds — not validated for continuous multi-GPU data-center duty. The table below sets out what actually differs for an AI server deployment.
| ToneCooling Industrial Assembly | Typical Consumer / Gaming Liquid Cooling | |
|---|---|---|
| Quality system | ISO 9001:2015, IATF 16949-aligned manufacturing | Typically no formal quality-management certification disclosed |
| Duty cycle | Engineered for continuous 24/7 data-center operation | Designed for consumer desktop use, not validated for continuous multi-GPU server duty |
| Customization | Engineered to your baseboard drawing, with DFM review per RFQ | Fixed-fit retail SKU, no per-project engineering review |
| Manufacturing scale | 30,000 m² ISO-certified facility, operating since 2004 | Boutique / enthusiast production scale |
| Reliability testing | 100% helium leak tested (<1.0×10-9 Pa·m³/s) and full-load thermal validated, per unit | Typically sample-tested, not validated per unit |
| Procurement model | RFQ, DFM review, NDA, prototype-to-production support | Retail / e-commerce checkout |
Comparison reflects typical consumer liquid-cooling product positioning as publicly described by those vendors; individual products vary. ToneCooling's H200 assembly is engineered and validated specifically for AI server and data-center deployment.
Process, quality, and manufacturing disclosure
| Process options | FSW, vacuum brazing, CAB, and TLP diffusion bonding in copper (C1100) and aluminium (6061); CFD flow/thermal validation; 100% helium leak testing. |
|---|---|
| Quality | ISO 9001:2015 certified; IATF 16949-aligned quality system; 100% helium leak testing; thermal resistance, leak, and flatness test reports available. |
| US support role | ToneCooling Texas handles RFQ intake, US-hours communication, NDA coordination, DFM follow-up, and US-side commercial routing for H200 cooling assembly programs. The Texas entity is a registered U.S. company (Austin, TX), not a manufacturing site. |
| Manufacturing disclosure | Manufacturing is performed by ToneCooling Technology Co., Ltd at the 30,000 m² facility in Huizhou, Guangdong, China (since 2004). ToneCooling Texas LLC is the North American RFQ and engineering-communication entity and does not manufacture. |
Ready to discuss your liquid cooling project?
An engineer reviews every RFQ and replies by email with next steps. Send drawings, specs, or a project description.
Common questions from US engineering & procurement teams
Do you supply liquid cooling for NVIDIA H200 servers?
Yes. ToneCooling Texas coordinates US RFQs for a complete direct-to-chip liquid cooling assembly covering 8× NVIDIA H200 GPUs and 4× NVSwitch devices, designed for high-density AI servers, HPC systems, and data centers.
Is this a bare cold plate or a complete assembly?
This is a complete, ready-to-install assembly — 8 copper GPU cold plates, 4 copper NVSwitch cold plates, 2 inlet/outlet manifolds with integrated flow distribution, 12 EPDM flexible hose assemblies, and 12 leak-free color-coded quick disconnects.
What heat load and flow rate is the H200 assembly validated for?
Validated total heat load is 6.344 kW (700 W × 8 GPU + 186 W × 4 NVSwitch) at 45°C inlet water temperature, with a recommended flow rate of 10 LPM, maximum pressure drop of 40 kPa, and system thermal resistance below 0.0055°C/W.
What reliability testing does the H200 assembly undergo?
Every assembly passes 100% helium leak testing (below 1.0×10-9 Pa·m³/s), a 1 MPa / 5-minute pressure hold with no leakage, full-load thermal performance validation, and corrosion resistance testing.
Where is the H200 cooling assembly manufactured?
Manufacturing is performed at the ToneCooling facility in Huizhou, Guangdong, China. ToneCooling Texas LLC (Austin, TX) is the US RFQ and engineering-coordination entity and does not manufacture.
Is this the same as gaming PC liquid cooling?
No. This is an engineered industrial assembly validated to ISO 9001:2015 / IATF 16949-aligned processes, 100% helium leak tested, and built to your baseboard drawing for continuous data-center duty — not a fixed-fit consumer water-cooling product designed for desktop use.