USA / NVIDIA GB300 / 4 GPU + 2 CPU / DIRECT-TO-CHIP

GB300 Cold Plate for NVIDIA GB300 NVL72 Trays — 4 GPU + 2 CPU Kit, USA

Direct Answer:

A GB300 cold plate is a direct-to-chip liquid cold plate that mounts on the GPUs and CPUs of an NVIDIA GB300 compute tray and moves their heat into facility coolant. ToneCooling supplies one configuration — the 4 GPU + 2 CPU kit, part number TC-BZP-GB300-01A — according to its spec sheet, with US RFQ support from ToneCooling Texas LLC in Austin, TX.

What to send with a GB300 RFQ:
  • Tray drawing or 3D model (STEP)
  • Coolant type and inlet temperature
  • Available flow rate per tray
  • Manifold and quick-disconnect interface
  • Sample quantity and annual volume
  • US delivery location (for DDP scoping)

ToneCooling Texas LLC coordinates US quotations for the GB300 4 GPU + 2 CPU cold plate kit. Cold plates are made in our own manufacturing facility in Huizhou; custom samples are available from a single piece. An engineer reviews every RFQ and replies by email with next steps.

Engineer-reviewed RFQsSamples from a single pieceISO 9001:2015 + IATF 16949-aligned100% helium leak-tested
DEFINITION

What is a GB300 cold plate, and why is it supplied as a 4 GPU + 2 CPU kit?

NVIDIA GB300 NVL72 is a liquid-cooled, rack-scale platform. According to NVIDIA’s GB300 NVL72 platform overview, one rack integrates 72 Blackwell Ultra GPUs and 36 Grace CPUs — a 2:1 GPU-to-CPU ratio. A tray-level GB300 cold plate kit covers four GPUs and two CPUs with a dedicated direct-to-chip cold plate and routes coolant through an adapter manifold to the rack’s quick disconnects.

ToneCooling supplies exactly this tray-level kit: 4 GPU cold plates + 2 CPU cold plates, sold as one part number, TC-BZP-GB300-01A. It is a standard part supplied according to its spec sheet. Any other GPU/CPU count, envelope, or port layout is quoted as a custom liquid cold plate project after a DFM review.

GB300 cold plate specs at a glance:
  • Kit: TC-BZP-GB300-01A — 4 GPU + 2 CPU cold plates, 1 manifold, 2 quick disconnects, 10 hoses
  • GPU cold plate (measured): 0.0133 °C/W, 12.06 kPa at 1.7 L/min, 1,066.94 W
  • CPU cold plate (measured): 0.0220 °C/W, 10.39 kPa at 0.7 L/min, 485.46 W
  • Design envelope: pure water or PG25, 2–4 L/min per cold plate, 20–30 °C inlet, working pressure up to 3 bar
  • Source: GB300 datasheet TC-DS-GB300-01A Rev. B — full GB300 cold plate spec table
KIT CONTENTS

What is included in the GB300 4 GPU + 2 CPU kit?

ItemQuantity per kitSource
GB300 GPU liquid cold plate4Our own manufacturing facility in Huizhou
GB300 CPU liquid cold plate2Our own manufacturing facility in Huizhou
Manifold (coolant supply / return)1Supplied by ToneCooling from China
Hoses / tubes10Supplied by ToneCooling from China
Quick disconnect (color-coded)2Supplied by ToneCooling from China

The complete kit ships under one part number, TC-BZP-GB300-01A. Dimensions, interfaces, and acceptance criteria follow the GB300 spec sheet; the test summary can be downloaded without a form (see GB300 cold plate specs below), and the STEP model and leak test records are available on request.

GB300 COLD PLATE SPECS

What are the GB300 cold plate specs?

The GB300 cold plate kit TC-BZP-GB300-01A is a 4 GPU + 2 CPU direct-to-chip kit whose GPU cold plate measured 0.0133 °C/W and 12.06 kPa pressure drop at 1.7 L/min and 1,066.94 W, and is designed for 2–4 L/min per cold plate with pure water or PG25. The table combines measured values and the design operating envelope from the GB300 datasheet.

SpecificationGB300 4G+2C kit (TC-BZP-GB300-01A)
Part number / configurationTC-BZP-GB300-01A — 4 GPU + 2 CPU (4G+2C) kit, standard product
Kit contents4 GPU cold plates (copper micro-channel), 2 CPU cold plates, 1 manifold, 2 quick disconnects, 10 hoses
GPU cold plate — measured1,066.94 W at 1.7 L/min; ΔP 12.06 kPa; thermal resistance 0.0133 / 0.0130 °C/W (T1 / T2)
CPU cold plate — measured485.46 W at 0.7 L/min; ΔP 10.39 kPa; thermal resistance 0.0220 °C/W
Test inlet temperatureGPU 19.9 °C (67.8 °F); CPU 23.6 °C (74.5 °F); pure water, steady state
Thermal interface material (test)TC-5888 thermal paste
Design coolantPure water or PG25
Design flow per cold plate2–4 L/min (0.53–1.06 gal/min)
Pressure-drop design target< 40 kPa (5.8 psi) at 3 L/min
Design heat loadGPU 800–1,200 W per GPU; CPU 350–600 W
Design inlet temperature20–30 °C (68–86 °F)
Working pressure≤ 3 bar (43.5 psi)
Leak and pressure testingEvery kit leak-tested before shipment; pressure and pressure-holding tests during production
Surface finishBlack textured baking paint

Source: ToneCooling GB300 datasheet TC-DS-GB300-01A Rev. B (October 2026); measured values from ToneCooling steady-state tests with pure water on 2026-03-20. US customary values in parentheses are calculated conversions. Final performance depends on system integration, flow distribution, coolant, clamping force, TIM, and rack cooling architecture.

Download the GB300 cold plate datasheet summary (PDF, TC-BZP-GB300-01A)   Request the full datasheet and STEP model

MEASURED TEST DATA

What do batch-validation tests show for the GB300 cold plates?

ToneCooling steady-state batch validation testing (pure water) measured the following on the GPU and CPU cold plates used in the 4G+2C kit. Values are measured results, not design targets.

MetricGPU cold plate (×4 per kit)CPU cold plate (×2 per kit)
Flow rate1.7 L/min0.7 L/min
Heat load tested1066.94 W485.46 W
Coolant temperature19.9 °C (67.8 °F) inlet → 27.3 °C (81.1 °F) outlet—
Thermal resistance0.0130–0.0133 °C/W0.0220 °C/W
Pressure drop12.06 kPa10.39 kPa

Test basis: ToneCooling steady-state test with pure water, test date 2026-03-20 (GB300 datasheet TC-DS-GB300-01A Rev. B). Every kit is 100% helium leak-tested before shipment. Results at your flow rate and coolant temperature are confirmed during quotation.

US RFQ PROCESS

How does a GB300 cold plate RFQ work for US buyers?

StepWhat happens
1. RFQ intakeSend tray drawing, coolant, flow, quantity, and delivery location. An engineer reviews every RFQ and replies by email with next steps.
2. NDAA mutual NDA is signed before any proprietary tray drawing is reviewed. See NDA & IP protection.
3. Spec-sheet matchEngineers confirm that your tray matches the 4G+2C kit, or flag the changes that make it a custom project.
4. SamplesCustom samples are available from a single piece; sample and prototype lead time is typically 4–6 weeks.
5. Production & deliveryVolume, schedule, and DDP terms are confirmed per order. See DDP shipping into the USA.

Planning a full rack deployment? Pair the cold plate kit with a coolant distribution unit (CDU) and review data center liquid cooling in the USA.

BUYER CHECKLIST

What should US buyers confirm before ordering GB300 cold plates?

QuestionWhere to check
Does our tray match the 4G+2C kit, or is it a custom layout?This page and the GB300 quotation guide
Sample vs. production lead timeCustom cold plate lead time (USA)
Tariffs and sourcingCold plate tariffs & Section 301 sourcing
Supplier qualificationHow to qualify a cold plate supplier
Older GPU platforms in the same fleetGB200, H200, and H100 cold plates
MANUFACTURING & US SUPPORT

Who manufactures the GB300 cold plates, and who supports US buyers?

Cold plate manufacturingOur own manufacturing facility in Huizhou, China — ToneCooling Technology Co., Ltd. (since 2004).
Kit accessoriesAdapter manifold, hose assembly, and quick-disconnect assembly are supplied by ToneCooling from China.
QualityISO 9001:2015 quality management; IATF 16949-aligned processes; 100% helium leak testing; thermal resistance, leak, and flatness test reports available.
Intellectual propertyToneCooling holds 2 invention patents + 6 utility model patents.
US support roleToneCooling Texas LLC (Austin, TX) handles RFQ intake, NDA coordination, and US-side commercial communication. The Texas entity does not manufacture.

Ready to quote a GB300 4 GPU + 2 CPU cold plate kit?

Send your tray drawing, coolant conditions, quantity, and delivery location. An engineer reviews every RFQ and replies by email with next steps.

FREQUENTLY ASKED

GB300 cold plate questions from US engineering & procurement teams

What is a GB300 cold plate?

A GB300 cold plate is a direct-to-chip liquid cold plate that mounts on the GPUs and CPUs of an NVIDIA GB300 compute tray and carries their heat into facility coolant. ToneCooling supplies it as one 4 GPU + 2 CPU kit, part number TC-BZP-GB300-01A, built to its spec sheet.

What are the GB300 cold plate specs?

The TC-BZP-GB300-01A kit has 4 GPU and 2 CPU cold plates. Measured: GPU 0.0133 °C/W and 12.06 kPa at 1.7 L/min and 1,066.94 W; CPU 0.0220 °C/W and 10.39 kPa at 0.7 L/min. Design envelope: pure water or PG25, 2–4 L/min per plate, 20–30 °C inlet, working pressure up to 3 bar.

Which GB300 configuration does ToneCooling supply?

One configuration only: the 4 GPU + 2 CPU (4G+2C) tray-level kit for GB300 NVL72 systems, part number TC-BZP-GB300-01A. Any other layout is handled as a custom cold plate project.

Is the GB300 cold plate a standard part or a custom part?

The 4G+2C kit is a standard part supplied according to its spec sheet. Different GPU or CPU counts, port positions, or envelopes are quoted as custom cold plates after a DFM review.

What test data is available for the GB300 cold plates?

ToneCooling steady-state batch validation testing with pure water on 2026-03-20 measured 0.0130–0.0133 °C/W thermal resistance and 12.06 kPa pressure drop on the GPU cold plate at 1.7 L/min and 1066.94 W, and 0.0220 °C/W and 10.39 kPa on the CPU cold plate at 0.7 L/min and 485.46 W.

Can we order a single GB300 sample kit?

Yes. Custom samples are available from a single piece. Sample and prototype lead time is typically 4–6 weeks; production volume and schedule are confirmed per RFQ.

Where are GB300 cold plates manufactured?

The cold plates are made in our own manufacturing facility in Huizhou, China (ToneCooling Technology Co., Ltd.). The adapter manifold, hose assembly, and quick-disconnect assembly in the kit are supplied by ToneCooling from China. ToneCooling Texas LLC in Austin, TX handles US RFQs and does not manufacture.

How do I request a GB300 cold plate quotation in the US?

Send your tray drawing or model, coolant type and inlet temperature, available flow, quantity, and delivery location through the RFQ form. An engineer reviews every RFQ and replies by email with next steps. A mutual NDA can be signed before drawing review.

Does ToneCooling publish a price for the GB300 cold plate?

No. Pricing depends on quantity, delivery terms, and any custom changes, and is confirmed per RFQ.

Can I download the GB300 cold plate datasheet?

Yes. A datasheet summary (PDF, TC-BZP-GB300-01A) with the measured test data can be downloaded from this page without a form. The full datasheet and STEP model are available on request.

What does NVL72 mean in GB300 NVL72?

NVL72 is the name of NVIDIA’s rack-scale configuration: according to NVIDIA’s GB300 NVL72 platform overview, one rack integrates 72 Blackwell Ultra GPUs and 36 Grace CPUs. ToneCooling’s tray-level kit cools four of those GPUs and two of those CPUs, so the rack’s 72 GPUs and 36 CPUs correspond to 18 kits.

Prepared by the ToneCooling Engineering Team. Last updated November 3, 2026.