Liquid Cold Plate Supplier for Northern Virginia Data Centers
ToneCooling Texas supports Northern Virginia data-center operators and integrators with liquid cold plate RFQs for AI and GPU racks, direct-to-chip cooling, and rack manifolds — with US-hours coordination, CFD review, and prototype support.
- 2D or 3D drawings
- Heat load and heat-source map
- Coolant, flow rate, and pressure-drop limit
- Envelope, mounting, and port layout
- Material and joining preference
- Prototype quantity and annual volume
ToneCooling Texas LLC is the North American RFQ and engineering route for teams deploying high-density compute in the Northern Virginia market (Ashburn, Loudoun County, and the wider Data Center Alley). US-hours DFM review, engineer-reviewed RFQs, and production through our 30,000 m² ISO 9001:2015-certified, IATF 16949-aligned facility in Huizhou, China (since 2004).
Direct engineering scope for Northern Virginia data centers
ToneCooling Texas supports teams building and operating high-density compute in the Northern Virginia market (Ashburn, Loudoun County, and the wider Data Center Alley) with custom liquid cold plates and direct-to-chip cooling hardware.
Application fit: GB200-class accelerators, H100/H200 platforms, CPU/GPU direct-to-chip modules, rack manifolds, and CDU-connected liquid cooling loops.
Cold plate solutions for US AI & data-center programs
Six product lines coordinated through ToneCooling Texas — click any card for specs and RFQ details.

NVIDIA GB300 Cold Plates
Direct-to-chip 4 GPU + 2 CPU kit (TC-BZP-GB300-01A) with adapter manifold, hoses, and quick disconnects.
View GB300 →
GPU Cold Plates
Direct-to-chip GPU cold plates for AI server racks, with manifold and QDC routing.
View GPU cold plates →
Server CPU Cold Plates
Copper direct-to-chip cold plates for AMD EPYC and Intel Xeon server CPUs.
View server CPU →
Data Center Liquid Cooling
Rack-level and direct-to-chip cooling support for US data-center deployments.
Explore data center →
IGBT / SiC Cold Plates
Cold plates for IGBT/SiC power modules, inverters, and traction electronics.
View IGBT cooling →
EV Battery Cold Plates
Aluminum cold plates for EV battery packs, inverters, and BESS.
View EV cooling →Validated AI-server cold plates (reference specs)
NVIDIA GB200 cold plate
| Heat dissipation (design-rated) | 1200 W + 1200 W (GPU) + 300 W (CPU) |
|---|---|
| Material | Purple copper (Cu T2) |
| Joining | Nitrogen-protection brazing + laser welding |
| Working point | 25 ± 2 °C, 2.5 L/min, pure water |
| Flow resistance | 35 ± 5 kPa |
| Cold-plate surface temp | below 43 °C |
| Pressure | 0.6 MPa |
| Dimensions | 235 × 190 × 30 mm |
NVIDIA H200 cold plate
| Heat dissipation (design-rated) | 8 × 700 W + 2 × 134 W + 2 × 156 W |
|---|---|
| Material | Purple copper (Cu T2) |
| Joining | Continuous nitrogen-protection brazing (tunnel furnace) |
| Working point | 38 °C, 8.0 LPM, pure water |
| Flow resistance | 18.5 kPa (±20%) |
| Cold-plate surface temp | below 65 °C |
| Pressure | 0.8 MPa |
| Dimensions | GPU 151 × 78.2 × 43.14 mm; switch 80 × 64.3 × 7.6 mm |
Specifications are typical validated values at the stated working point; final values are confirmed per drawing, heat load, flow rate, pressure-drop limit, and annual volume.
Process, quality, and manufacturing disclosure
| Process options | FSW, vacuum brazing, CAB, and TLP diffusion bonding in copper (C1100) and aluminum (6061); CFD flow/thermal validation; 100% helium leak testing. |
|---|---|
| Quality | ISO 9001:2015 certified; IATF 16949-aligned quality system; 100% helium leak testing; thermal resistance, leak, and flatness test reports available. |
| US support role | ToneCooling Texas handles RFQ intake, US-hours communication, NDA coordination, DFM follow-up, and US-side commercial routing for Northern Virginia data-center programs. The Texas entity is a registered U.S. company (Austin, TX), not a local Northern Virginia office. |
| Manufacturing disclosure | Manufacturing is performed by ToneCooling Technology Co., Ltd at the 30,000 m² facility in Huizhou, Guangdong, China (since 2004). ToneCooling Texas LLC is the North American RFQ and engineering-communication entity and does not manufacture. |
Ready to discuss your liquid cooling project?
An engineer reviews every RFQ and replies by email with next steps. Send drawings, specs, or a project description.
Common questions from US engineering & procurement teams
Do you supply cold plates for Northern Virginia data centers?
Yes. ToneCooling Texas coordinates US RFQs for liquid cold plate and direct-to-chip projects serving the Northern Virginia market and routes engineering review through ToneCooling's thermal team.
Do you have a physical office in Northern Virginia?
ToneCooling Texas LLC is a U.S. entity registered in Austin, Texas. We support Northern Virginia customers in US time zones; manufacturing is in Huizhou, Guangdong, China.
Which AI server platforms do you support?
GB200-class accelerators, H100/H200 platforms, and CPU/GPU direct-to-chip modules, with manifold and CDU-loop review.
What is the lead time for prototypes?
Prototype lead time is typically 4–6 weeks after drawing approval; production timelines depend on volume and process and are confirmed per RFQ.