USA / NORTHERN VIRGINIA / DATA CENTER ALLEY — RFQ COORDINATION

Liquid Cold Plate Supplier for Northern Virginia Data Centers

Direct Answer:

ToneCooling Texas supports Northern Virginia data-center operators and integrators with liquid cold plate RFQs for AI and GPU racks, direct-to-chip cooling, and rack manifolds — with US-hours coordination, CFD review, and prototype support.

RFQ inputs for faster DFM review:
  • 2D or 3D drawings
  • Heat load and heat-source map
  • Coolant, flow rate, and pressure-drop limit
  • Envelope, mounting, and port layout
  • Material and joining preference
  • Prototype quantity and annual volume

ToneCooling Texas LLC is the North American RFQ and engineering route for teams deploying high-density compute in the Northern Virginia market (Ashburn, Loudoun County, and the wider Data Center Alley). US-hours DFM review, engineer-reviewed RFQs, and production through our 30,000 m² ISO 9001:2015-certified, IATF 16949-aligned facility in Huizhou, China (since 2004).

Engineer-reviewed RFQs (Central Time)US-hours engineering & DFM reviewISO 9001:2015 certified · IATF 16949-alignedGB200-class & direct-to-chip experience
ENGINEERING SCOPE

Direct engineering scope for Northern Virginia data centers

ToneCooling Texas supports teams building and operating high-density compute in the Northern Virginia market (Ashburn, Loudoun County, and the wider Data Center Alley) with custom liquid cold plates and direct-to-chip cooling hardware.

Application fit: GB200-class accelerators, H100/H200 platforms, CPU/GPU direct-to-chip modules, rack manifolds, and CDU-connected liquid cooling loops.

REFERENCE COLD PLATES

Validated AI-server cold plates (reference specs)

NVIDIA GB200 cold plate

NVIDIA GB200 direct-to-chip liquid cold plate in purple copper with hoses and quick disconnects, supplied by ToneCooling Texas LLC
Heat dissipation (design-rated)1200 W + 1200 W (GPU) + 300 W (CPU)
MaterialPurple copper (Cu T2)
JoiningNitrogen-protection brazing + laser welding
Working point25 ± 2 °C, 2.5 L/min, pure water
Flow resistance35 ± 5 kPa
Cold-plate surface tempbelow 43 °C
Pressure0.6 MPa
Dimensions235 × 190 × 30 mm

NVIDIA H200 cold plate

NVIDIA H200 liquid cold plate (GPU + switch) in purple copper, supplied by ToneCooling Texas LLC
Heat dissipation (design-rated)8 × 700 W + 2 × 134 W + 2 × 156 W
MaterialPurple copper (Cu T2)
JoiningContinuous nitrogen-protection brazing (tunnel furnace)
Working point38 °C, 8.0 LPM, pure water
Flow resistance18.5 kPa (±20%)
Cold-plate surface tempbelow 65 °C
Pressure0.8 MPa
DimensionsGPU 151 × 78.2 × 43.14 mm; switch 80 × 64.3 × 7.6 mm

Specifications are typical validated values at the stated working point; final values are confirmed per drawing, heat load, flow rate, pressure-drop limit, and annual volume.

MANUFACTURING ROUTE

Process, quality, and manufacturing disclosure

Process optionsFSW, vacuum brazing, CAB, and TLP diffusion bonding in copper (C1100) and aluminum (6061); CFD flow/thermal validation; 100% helium leak testing.
QualityISO 9001:2015 certified; IATF 16949-aligned quality system; 100% helium leak testing; thermal resistance, leak, and flatness test reports available.
US support roleToneCooling Texas handles RFQ intake, US-hours communication, NDA coordination, DFM follow-up, and US-side commercial routing for Northern Virginia data-center programs. The Texas entity is a registered U.S. company (Austin, TX), not a local Northern Virginia office.
Manufacturing disclosureManufacturing is performed by ToneCooling Technology Co., Ltd at the 30,000 m² facility in Huizhou, Guangdong, China (since 2004). ToneCooling Texas LLC is the North American RFQ and engineering-communication entity and does not manufacture.

Ready to discuss your liquid cooling project?

An engineer reviews every RFQ and replies by email with next steps. Send drawings, specs, or a project description.

FREQUENTLY ASKED

Common questions from US engineering & procurement teams

Do you supply cold plates for Northern Virginia data centers?

Yes. ToneCooling Texas coordinates US RFQs for liquid cold plate and direct-to-chip projects serving the Northern Virginia market and routes engineering review through ToneCooling's thermal team.

Do you have a physical office in Northern Virginia?

ToneCooling Texas LLC is a U.S. entity registered in Austin, Texas. We support Northern Virginia customers in US time zones; manufacturing is in Huizhou, Guangdong, China.

Which AI server platforms do you support?

GB200-class accelerators, H100/H200 platforms, and CPU/GPU direct-to-chip modules, with manifold and CDU-loop review.

What is the lead time for prototypes?

Prototype lead time is typically 4–6 weeks after drawing approval; production timelines depend on volume and process and are confirmed per RFQ.